Call Us
+8615579917678
E-mail Us
The refrigerated dryer mainly uses the refrigerant and compressed air for heat exchange, and reduces the compressed air temperature to the dew point temperature in the range of 2 ~ 10℃, so that the water content in the compressed air tends to the state of supersaturation, so as to remove the water in the compressed air to ensure the stability of production. harmful substances pollution.
A Refrigerated Dryer is essential for maintaining the quality and efficiency of compressed air systems in various industrial applications. By cooling the compressed air to a temperature below its dew point, these dryers effectively remove moisture, preventing corrosion, freeze-ups, and equipment damage.
Why Choose Us?
With years of experience in compressed air technology, we provide top-of-the-line Refrigerated Dryers that combine innovation, reliability, and efficiency. Our team of experts is dedicated to offering customized solutions tailored to your specific requirements, ensuring that you receive the best value and performance for your investment.
1.Energy saving
The aluminum alloy three-in-one heat exchanger design minimizes the process loss of cooling capacity and improves the recovery and utilization of cooling capacity. Under the same processing capacity, the total input power of this model is reduced by 15-3096.
2.Efficient
The integrated heat exchanger is equipped with guide fins to allow the compressed air to exchange heat evenly inside. The built-in air-water separation device is equipped with a stainless steel filter to separate the water.
A more complete separation.
3.intelligent
Multi-channel temperature and pressure monitoring, real-time display of dew point temperature, automatic recording of cumulative operating time, self-diagnosis function, display of corresponding alarm codes, and automatic protection of equipment.
4.Environmental friendly
In response to the international Montreal Protocol, this series of models all use R1348 and R410a environmentally friendly refrigerants, which have zero damage to the atmosphere and adapt to international Market demand.
5.Stablize
Standard constant pressure expansion room and standard intelligent temperature control. In laboratory tests, when the inlet air temperature reaches 659°C and the ambient temperature reaches 42°C, it still operates stably. It also has temperature and pressure double anti-freeze protection, and can operate at low temperatures for a long time. During load operation, the output of the compressor is automatically stopped, and the cooling capacity retained by the aluminum plate exchanger is used to provide heat exchange. While saving energy, it also extends the service life of the equipment.
Contact us today to explore our range of Refrigerated Dryers and discover how we can help enhance the efficiency and reliability of your compressed air systems.
Model | Nominal Power | Working Pressure | Free Air Delivery | |||
KW | HP | bar | psi | m3/min | cfm | |
KPPF-10A | 0.22 | 0.3 | 8 | 116 | 1.20 | 42.38 |
KPPF-20A | 0.42 | 0.58 | 8 | 116 | 2.40 | 84.76 |
KPPF-30A | 0.59 | 0.8 | 8 | 116 | 3.60 | 127.13 |
KPPF-50A | 0.73 | 1.0 | 8 | 116 | 4.80 | 169.51 |
KPPF-75A | 0.88 | 1.2 | 8 | 116 | 7.20 | 254.27 |
KPPF-100A | 1.76 | 2.4 | 8 | 116 | 12.00 | 423.78 |
KPPF-120A | 2.06 | 2.8 | 8 | 116 | 14.40 | 508.53 |
KPPF-150A | 2.35 | 3.2 | 8 | 116 | 18.00 | 635.66 |
KPPF-200A | 2.94 | 4.0 | 8 | 116 | 24.00 | 847.55 |
KPPF-250A | 3.53 | 4.8 | 8 | 116 | 30.00 | 1059.44 |
AIR COMPRESSOR MAINTENANCE
01
The air compressor shouldbe placed in a place withclean air and good ventilation.
02
The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.
03
Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.
04
When wiring, check whether thefan rotation direction is consistentwith the arrow direction.
ENERGY SAVING THCHNOLOGY
The starting power of the original system is 555kw,and the starting power of the new system is 320kw.
Power saving of 17000o kWh per month
The starting power of the original system is 240kW,and the starting power of the new system is 132kw.
Power saving of 54000 kWh per month
The starting power of the original system is 446kW,and the starting power of the new system is 325kW.
Power saving of 86000 kWh per month
The starting power of the original system is 690kw,and the starting power of the new system is 420kw.
Power saving of 260000 kWh per month
The starting power of the original system is 732kW,and the starting power of the new system is 50okw.
Power saving of 167000 kWh per month
The starting power of the original system is 430kw,and the starting power of the new system is 320kw.
Power saving of 79000 kWh per month
RELATED PRODUCTS
Inquiry